§ 13.36.070. Installation depth—Distance from structures.  


Latest version.
  • A.

    No building sewer or other drainage piping or part thereof, which is constructed of materials other than those approved for use under or within a building, shall be installed under or within two feet (0.6m) of any building or structure, or part thereof, nor less than one foot (0.3m) below the surface of the ground. The provisions of this subsection include structures such as porches and steps, whether covered or uncovered, breezeways, roofed porte-cocheres, roofed patios, carports, walks, covered driveways, and similar structures or appurtenances (CPC § 718.3).

    B.

    Cast iron or asbestos cement pipe of four inch diameter or less is to be installed in half-lengths only.

(Ord. 1109 § 1 (part), 1996: prior code § 5525)